| Technical characteristics of the drying plant ACM-2000 | ||
|---|---|---|
| Drying plant size (length x width x height) | mm | 7100x1900x2700 |
| Number of chambers and carrier | kom | 5 |
| Weight of the empty drying plant | kg | 1400 |
| Size of the tray (shelf) | mm | 800×1600 |
| Number of shelves by carriers and the total number of shelves | kom | 21(105) |
| Quantity of the products per shelf (based on plum) | kg | 20 |
| Capacity of the drying plant based on plum | kg | 2100 |
| Maximum flow of one ventilator | m3/h | 8000 |
| Installed heating capacity | kW | 70 |
| Installed power capacity | kW | 28,4 |
| Maximum electrical consumption per 1 kg of prunes with pits (24h) | kWh | 1,36 |
| Losses of heat conduction through a sheath (24 h) | kWh | 21,4 |
| Maximum water temperature in the system | ℃ | 75 |
| Maximum air temperature in the drying plant | ℃ | 65 |
| Hook up cable | Cu | 5x16mm2 |
| Power supply | 3×380 V,50Hz, AC | |
| Main fuses | A | 63 |
| COP of heat pump air to water (A20/W65) | 3,10 | |
| COP drying plants | 2,95 | |
| Max. moisture extraction rate – MER | kg/h | 200 |
| SMER specific moisture extracted ratio in respect to input energy | kg/kWh | 2,93 |